3 Phase Outdoor Disconnect

3 Phase Outdoor Disconnect

Details
This series of 3 phase outdoor disconnect is suitable for distribution lines operating at 50Hz AC and rated voltages up to 500V.
Category
Outdoor Disconnect Switch
Share to
Send Inquiry
Description
Technical Parameters

Product Description

HR20-05H
HR20-05type2
HR20-05

This series of 3 phase outdoor disconnect is suitable for distribution lines operating at 50Hz AC and rated voltages up to 500V. They provide short-circuit and overload protection for the low-voltage side of transformers. Under certain conditions, they can switch unloaded transformers, unloaded lines, and rated operating current. They cleverly combine the isolation function of a disconnector with the short-circuit protection of a high-voltage fuse, creating a compact, versatile, and economical combination device. The disconnector itself establishes a clearly visible, safety-compliant disconnect point in the circuit, ensuring reliable isolation from the power source during equipment overhaul or line maintenance, greatly enhancing the safety of electrical operations. Furthermore, because they are designed for outdoor environments, these devices typically feature a high degree of protection (e.g., IP rating). Their housing and insulation components effectively withstand harsh weather conditions such as wind, rain, snow, dust, ultraviolet light, and moisture and salt spray, ensuring long-term operational stability and reliability.

Code Meaning

 

HR20-0.5H
HR: Outdoor fused disconnector
20: Design code
0.5: Rated voltage
H: Silicone type

 

Standards

 

GB/T14048.3
IEC60947-3

 

Technical Parameters

 

Code

Rated voltage

Rated current

Breaking current A

HR20-0.5H/400A

0.5kV

400A

30-400

HR20-0.5H/600A

0.5kV

600A

30-600

HR20-0.5H/800A

0.5kV

800A

30-800

HR20-0.5H/1000A

0.5kV

1000A

30-1000

 

Normal Operating and Installation Conditions

 

1. Ambient air temperature must not exceed +40°C and not fall below -5°C.


2. The installation location must not exceed 2000m above sea level.


3. Humidity: At a maximum temperature of +40°C, the relative humidity must not exceed 50%. Higher relative humidity is permitted at lower temperatures, for example, up to 90% at 20°C. Special measures must be taken to prevent occasional condensation caused by temperature fluctuations.


4. The ambient pollution level must be Level 3.


5. The switch must be installed in an area free from significant shaking, impact, or vibration. The installation location must be free of explosive media and free of gases and dust that could corrode metal or damage insulation.

 

Dimension

 

image001

 

Our Advantage

 

  • Lower prices
  • Higher quality
  • Faster communication and response times
  • Deeper technical support and potential for collaborative development
  • A more stable and reliable long-term partner

 

Packing

 

Carton / Wooden case / Pallet

 

FAQ

 

Q:  Does this disconnect switch have two base types?

A:  Yes, as shown in the dimensional diagram above, there are two base types for you to choose from.

Q: How many poles can I choose?

A:  Three phase and four phase.

Q: How to do when my drawing differs with your dimension?

A:  Please send us your drawing for reference first, then we would adjust dimension and accessories as you need.

Q:  What precautions should be taken during installation?

A:  Operating the circuit breaker with load is strictly prohibited. Ensure that all downstream loads are disconnected (i.e., there is no current flowing in the circuit) before opening or closing the circuit breaker. Operating the circuit breaker with load on will generate a large arc and is extremely dangerous.

 

 

Hot Tags: 3 phase outdoor disconnect, China 3 phase outdoor disconnect manufacturers, suppliers, factory