Product Description


400 amp outdoor low-voltage disconnect switches are suitable for 0.5kV, 50Hz distribution lines. Outdoor disconnectors serve as protection and overload protection for the low-voltage side of transformers. Under certain conditions, they can be used for no-load transformers, no-load lines and rated working currents.Complies with standards: GB/T14048.3, IEC 60947-3.
Technical Parameters
(H)JDW2-0.5
|
Code |
Rated voltage |
Rated current |
Breaking current |
|
(H)JDW2-0.5/400 |
0.5kV |
400A |
30-400A |
|
(H)JDW2-0.5/500 |
0.5kV |
500A |
30-500A |
|
(H)JDW2-0.5/600 |
0.5kV |
600A |
30-600A |
|
(H)JDW2-0.5/800 |
0.5kV |
800A |
30-800A |
|
(H)JDW2-0.5/1000 |
0.5kV |
1000A |
30-1000A |
Main features
1. During electrical equipment maintenance, an electrical separation and a clearly visible disconnect point are required to ensure the safety of maintenance personnel.
2. Isolators must not be operated under load: they cannot operate with rated or high loads, and cannot open or close load currents or short-circuit currents. However, those with arc extinguishing chambers can operate with light loads and no-load lines.
3. During normal power-on operation, close the isolator first, then the circuit breaker or load switch. During power-off operation, open the circuit breaker or load switch first, then the isolator.
4. When selecting an isolator, as with other electrical equipment, its rated voltage, rated current, dynamic stability current, thermal stability current, etc. must meet the requirements of the application.
Environmental Condition
- Altitude not exceeding 2000 meters.
- Ambient temperature not exceeding +40°C and not below -25°C.
- Relative humidity not exceeding 85% (relative to +20±5°C).
- Store in a well-ventilated, dry environment free from combustion and explosion hazards, severe vibration and shock, and chemicals that are severely corrosive to metal and insulating materials.
Dimension

Note: All product information on the Internet is for reference only. If you have any questions, please contact us for verification and confirmation,
especially important parameters such as hole size and technical parameters. In order to avoid changes in the company's technological
updates or upgrades, which may cause you unnecessary losses, thank you for your cooperation!
FAQ
Q: What is its primary function of outdoor disconnectors?
A: An isolator switch is not a protection device; it is a manual switching device used only for isolation purposes once the circuit has already been de-energized by an upstream breaker.
Q: Do you offer OEM/ODM services? What are the requirements?
A: Yes, we do OEM/ODM. Get customer's technical data and product drawings first.
Q: What materials are outdoor isolator enclosures typically made from?
A: We have two main types, ceramic type disconnect switches and composite resin type disconnect switches
Q: What does the IP rating mean, and why is it critical for outdoor switches?
A: For outdoor use, a high IP rating is essential to withstand weather conditions like rain and dust.
Hot Tags: 400 amp disconnect single phase outdoor, China 400 amp disconnect single phase outdoor manufacturers, suppliers, factory