This gas-insulated circuit breaker with disconnector is 12KV 630A, which is used in gas insulated switchgear (GIS) to protect cables and machines from overloads, short circuits and insulation faults. As for the insulation components of circuit breaker are primarily made of environmentally friendly thermoplastic clinker with a recycling rate of up to 90%, which follow the concept of sustainable development and eco-friendly development. This breaker combines a circuit breaker and disconnector into one unit, reducing costs and cabinet size. The integrated operating mechanism of the circuit breaker and disconnector allows for more safe maintenance.
The main circuit is 630A-20kA, 25kA(3 seconds), with a mechanical life of 10,000 times. The grounding circuit is 20kA (2s), and the mechanical life is 2000 times.
Product Application
Gas-filled cabinets (GIS)
GIS use low-pressure SF₆ gas, N₂, or a mixed gas (SF₆ + N₂) as the insulation medium for switchgear. They centrally house high-voltage electrical components such as circuit breakers, disconnectors, earthing switches, and transformers within a sealed, stainless steel enclosure.
The gas-filled cabinet circuit breaker featured on this page combines a circuit breaker and disconnector into one unit, reducing costs and cabinet size. The integrated operating mechanism of the circuit breaker and disconnector allows for safe maintenance.
The key advantage of gas-filled cabinets is their immunity to environmental conditions such as condensation, contamination, small animals, and chemicals, making them suitable for use in harsh environments. Another important feature is that the excellent performance of SF₆ insulation significantly reduces the cabinet's overall dimensions, facilitating miniaturization. Compared to air insulation, SF₆... Gas-filled cabinets occupy 26% of the installation area and 27% of the volume. Furthermore, the use of high-performance oil-free switches (vacuum or SF₆) significantly reduces maintenance and overhaul workloads.
Environmental Condition
1) Ambient Temperature: Maximum +40°C, Minimum -15°C (Storage and transportation at -30°C permitted);
2) Altitude: ≤ 2000 meters;
3) Ambient Humidity: Daily average relative humidity < 95%, monthly average relative humidity ≤ 90%;
4) Earthquake Intensity: Not exceeding 8 degrees;
5) Operating Location: No flammable or explosive hazards, no water vapor, no chemically corrosive gases, and no severe vibration.
Note: For special operating conditions that differ from normal operating conditions, buyers should inform the manufacturer. For example, when electrical equipment is installed at an altitude of 2000 meters or above, this must be specifically noted so that we can make adjustments during production.
Product Parameters
| No. | Item | Unit | Data |
| 1 | Rated frequency | Hz | 50 |
| 2 | Rated current | A | 630 |
| 3 | Rated short-time withstand current | kA | 20/25 |
| 4 | Rated peak withstand current | kA | 50 |
| 5 | Rated short-circuit duration | s | 4 |
| 6 | Rated short-circuit closing current | kA | 50 |
| 7 | Rated operating sequence | 0-0.3s-CO-180s-CO | |
Standard
GB/T1984 AC high voltage circuit breaker
Dimension

Our Clients




Our Advantage
10 years+ manufacture experience
Complete production technology and management
Greater flexibility to produce tailored or specialized products
Integrated supply chain
Strong after-sales service & support
Packing
Carton
Wooden Case
Pallet
FAQ
Q: Can I visit your factory?
A: Welcome to our factories, anytime.
Q: Where are you located?
A: Yueqing city, Zhejiang province.
Q: How long have you been manufacturing electrical products?
A: 10+ years. From the start, we do metal accessories then explore market in high voltage accessories in switchgear as well as switchgear shell.
Q: What should I do if I receive a damaged or defective product?
A: Please contact us immediately. We will find out the cause and do our best to make up for the loss.
Hot Tags: gas insulated breaker, China gas insulated breaker manufacturers, suppliers, factory, circuit breaker in gas insulated switchgear, Gas Insulated Breaker, Gas Insulated Circuit Breaker, Gas Insulated Substation Components, Gis Circuit Breaker