Since its founding in 2010, Granso's first factory has grown into one of China's largest metal component manufacturers. Granso specializes in producing components for switchgear ranging from 7.2kV to 40.5kV, such as interlocks, circuit breakers, load switches, earthing switches, vacuum circuit breakers, and insulation. Through partnerships with renowned brands such as CHNT, DELIXI, and HUAWEI, Granso's annual output value has reached US$60 million.

 
  • Gas Insulated Circuit Breaker
    Gas insulated circuit breaker with disconnector differs from others. While they are integrated, the disconnector is located above the circuit breaker. Consequently, the operating mechanisms for...
    view more
  • Gas Insulated Breaker
    This gas-insulated circuit breaker with disconnector is 12KV 630A, which is used in gas insulated switchgear (GIS) to protect cables and machines from overloads, short circuits and insulation faults.
    view more
  • Gas Insulated Substation Components
    12KV 1000A High-voltage circuit breakers ,like this kind gas insulated substation components, (often termed high-voltage switches) plays a critical role in SF₆ gas-insulated switchgears.
    view more
  • Gis Circuit Breaker
    Gis circuit breaker is a three-position circuit breaker with disconnector and grounding, which adopts a splint-type structure and has the characteristics of small size, reliable breaking...
    view more
 
Why Choose Us

 

Our Factory
Owning three factories with 23000+ square meters together, Granso now has over 200+ staff, 25+ technicians. The self-production rate of parts in our company is as high as over 90%.

 

Quality Control
We rigorously control every process, ensuring our products comply with relevant standards such as GB7251.1, GBT/23359, and JB/T9661.

 

One-Stop Service
In the pre-sales stage, our team of experts will recommend the most suitable products according to the needs of customers and provide detailed technical consultation.During the sales period, we ensure timely delivery and provide installation guidance.For after-sales, we provide long-term technical support, warranty services and spare parts to help customers maximize the use of products and get reliable maintenance during use.

 

 

Technical Parameters

 

 

No.

Item

Unit

Data

1

Rated frequency

Hz

50

2

Rated current

A

630

3

Rated short-time withstand current

kA

20/25

4

Rated peak withstand current

kA

50

5

Rated short-circuit duration

s

4

6

Rated short-circuit closing current

kA

50

7

Rated operating sequence

0-0.3s-CO-180s-CO

 

Advantages of Circuit Breaker in Gas-Insulated Switchgear

 

High Efficiency:

Circuit breaker in gas-insulated switchgear has higher efficiency than most other breakers because SF6 safely and quickly break high-voltage currents.

01

Excellent Insulation:

Circuit breaker in gas-insulated switchgear has strong insulation. It keeps the system safe from electrical arcs.

02

Low Maintenance:

These breakers are kept in good condition because the gas prevents the system from damage or wear.

03

Compact Size:

The high insulating strength of SF6 allows the equipment to be smaller in size, so it saves space.

04

Reliable Operation:

Circuit breaker in gas-insulated switchgear is reliable and strong. These breakers work well in a variety of weather and environmental conditions.

05

 

 

 

Gas Insulated Circuit Breaker

Applications of Circuit Breaker in Gas-Insulated Switchgear

 

 

Power Transmission & Distribution:

GIS circuit breakers are integral to the stable operation of electrical grids, reliably interrupting fault currents to prevent extended power outages and maintain grid stability.

Power Generation:

In power plants, GIS protects and controls the power flow from generators to the grid, handling high voltages and currents.

Space-Constrained Environments:

Due to their compact design and smaller clearances, GIS equipment with circuit breakers is perfect for urban areas, underground substations, and offshore platforms where space is limited.

Industrial & Sensitive Applications:

Industries such as petrochemical, mining, and data centers rely on GIS for their high reliability and ability to function in harsh environments with critical processes.

Renewable Energy:

In comparison with the type of equipment, wind farms and solar power plants prefer using GIS for more efficient energy transfer. This is because GIS guarantees stable power flow and electrical fault prevention which is vital for renewable energy projects.

 

Components of Circuit Breaker in Gas-Insulated Switchgear

 

 

Interrupter (Burning Chamber): This is the core component of a gas-insulated circuit breaker, responsible for extinguishing the arc. The arc extinguishing chamber contains the moving and stationary contacts, the insulating nozzle, and the associated arc-extinguishing mechanism.

 

Operating Mechanism: This component provides the mechanical energy required to open and close the circuit breaker. Common operating methods include manual and electric operation, with electric operation enabling remote control and automation.

 

Gas System and Density Monitoring: The circuit breaker is filled with SF6 gas at a specific pressure. A sophisticated gas system manages the filling, circulation, and sealing of the SF6 gas.

 

Insulation Support System: High-performance insulating materials such as porcelain post insulators, solid insulators (e.g., epoxy post insulators), or composite insulators are used to support and isolate live parts. This ensures excellent insulation performance under high voltage conditions.

 

Enclosure: Common structural types include:
Live Can (Porcelain Post): The circuit breaker consists of multiple independent phases, with the internal arc extinguishing chamber and other live parts of each phase supported by porcelain insulators.

 

Dead tank type (tank type): In this design, the interrupter, and sometimes even the disconnector, are integrated into a sealed metal tank filled with SF6 gas. This configuration is common in SF6 switchgear and SF6GIS devices. It is more compact, has better pollution resistance, and is safer to operate.

 

 

Packing and Shipping

 

 

Packing

Carton/ Wooden Case / Pallet

Shipping

Express, Air Freight, Sea Freight, LCL/FCL

 

 

FAQ

 

 

Q: Do you offer technical support?

A: For sure, any technical confusion, contact us anytime. If needed, a video call is welcome.

Q: What are your MOQs (Minimum Order Quantities)?

A: One piece.

Q: Do you provide installation, operation, or maintenance manuals? Where can I find/download them?

A: Yes, each product can be accompanied by an operation manual if you need.

Q: What shipping methods do you offer?

A: E.g., Express, Air Freight, Sea Freight, LCL/FCL

Q: Can you manufacture products according to specific customer drawings or specifications?

A: Yes, we can. We have strong manufacture might over 10+ years experience.

Q: How long does it usually produce?

A: Samples within 3 days, if purchase in bulk rely on the quantity.

Q: Why is the SF6 circuit breaker used?

A: The chemical properties of SF6 make it ideal for use within circuit breakers and switchgear. SF6 gas has excellent thermal transfer characteristics, so it works to absorb the energy of the arc. This creates resistance across the arcing contacts and eventually extinguishes the arc.

Q: What is the difference between air insulated switchgear and gas insulated switchgear?

A: Air insulated switchgear (AIS) uses air for insulation and is a cost-effective, easily maintainable, and flexible option for locations with ample space, while gas insulated switchgear (GIS) uses SF6 gas or other gases, offering compact designs, improved dielectric strength, and enhanced safety at a higher cost, making it ideal for congested, underground, or sensitive environments.

Q: How does a gas circuit breaker work?

A: Instead of oil, air, or a vacuum, a sulfur hexafluoride circuit breaker uses sulfur hexafluoride (SF6) gas to cool and quench the arc on opening a circuit. Advantages over other media include lower operating noise and no emission of hot gases, and relatively low maintenance.

Q: How can you tell if a circuit breaker is working?

A: To test if a breaker is good, use a voltage tester or digital multimeter to check for power at the terminals after turning off the breaker and removing all devices from the circuit, then turning the breaker on. A good breaker will supply the expected voltage (e.g., 120V for a single-pole breaker). Also, look for signs of physical damage like burn marks, smell for burning, or test the breaker's reset function by flipping it to the tripped position and back on.

We're professional circuit breaker in gas-insulated switchgear manufacturers and suppliers in China, specialized in providing high quality custom service. We warmly welcome you to buy circuit breaker in gas-insulated switchgear at competitive price from our factory.

Gas Insulated Breaker, Gas Insulated Circuit Breaker, Gis Circuit Breaker
Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.