This outcoming line operating mechanism of sf6 circuit breaker is suitable for a variety of indoor high-voltage SF6 load switchgear. This series of operating mechanism of sf6 circuit breaker adopts planar vortex springs to control the operation of load switches, and the grounding operation is controlled during the process by using compression springs. The working positions are three stations: closing, opening and grounding. The grounding and closing are equipped with mechanical interlocks to prevent misoperation. This product features a moderate volume, convenient installation and use, and strong adaptability.
This operating mechanism of sf6 circuit breaker complies with the relevant requirements of GB3804-2004 "3.6~40.5kv High Voltage AC Load Switch" and GB16926-2009 "AC High Voltage Load Switch Fuse Combined Electrical Apparatus".
Operating Instruction
1. Closing the Load Switch:
Fix the mechanism to the main unit. Use the dedicated operating handle, insert it into the mechanism's closing operating shaft (below), and rotate it clockwise to close the switch. Rotate the spring counterclockwise to charge energy, causing the mechanism to actuate the contacts and quickly close the load switch. Simultaneously, the spring charges energy in preparation for opening the switch, or the motor is energized to actuate the mechanism to complete the switch closing operation.
2. Opening the Load Switch:
Simply press the opening button to release the energy in the opening spring, causing the mechanism to actuate the main shaft for a rapid opening operation.
3. Closing the Load Switch:
Insert the operating handle into the grounding operating shaft (above) and rotate it 90° counterclockwise. The main unit, under the action of the mechanism's spring force, closes the grounding circuit.
4. Opening the Load Switch:
Turn the operating handle counterclockwise approximately 90°, causing the main unit, under the action of the mechanism's spring force, to open the grounding circuit.
Product Dimension
Supporting tailored size

Ordering Instructions
- When ordering an electric spring operating mechanism, please specify the voltage level (e.g., DC220, DC110, DC48, DC24, etc.).
- If a shunt trip coil is required, please specify the voltage level when ordering. Otherwise, it will be assumed to be the same voltage as the electric operating motor.
Our Clients




Our Advantage
10 years+ manufacture experience
Complete production technology and management
Greater flexibility to produce tailored or specialized products
Integrated supply chain
Centralized Pollution Control
Strong after-sales service & support
Packing
Carton
Wooden Case
Pallet
FAQ
Q: Can I get detailed technical drawings/datasheets/CAD files for this product?
A: Yes, welcome to contact us. We'll reply to you within 24 hours.
Q: Do you offer discounts for bulk orders? What are your MOQs (Minimum Order Quantities)?
A: The Minimum Order Quantity is 1 piece, and we offer big discounts for bulk orders, feel free to reach out.
Q: Can I place a sample order first? What is the cost and lead time for samples?
A: Yes, a trail order first to test and see the quality. The lead time for one sample would be 2 days. As for the quote, please contact us to get the latest price.
Q: What shipping methods do you offer?
A: Express, Air Freight, Sea Freight, LCL/FCL
Hot Tags: operating mechanism of sf6 circuit breaker, China operating mechanism of sf6 circuit breaker manufacturers, suppliers, factory, Motor Operating Mechanism, operating mechanism, operating mechanism of gas insulated switchgear, Operating Mechanism Of Sf6 Circuit Breaker, Sf6 Circuit Breaker Spring Mechanism, Spring Charged Mechanism Of Circuit Breaker