Four-pole load break disconnect is a key electrical component in low-voltage power distribution systems. They simultaneously close and isolate the neutral line (north pole) while opening and closing three-phase lines. The disconnect switches featured on this page are rated for 160A and are suitable for applications requiring complete power disconnection and absolute safety. When the system has single-phase loads or requires higher electrical isolation, the fourth pole effectively cuts off potential fault currents in the neutral line, preventing electric shock during maintenance and equipment commissioning, and providing the highest level of safety protection for operators. They offer high current handling and interrupting capacity, ensuring safe and reliable operation, making them widely used as main switches, branch switches, and for equipment maintenance isolation in various buildings and industrial projects.This product complies with standards GB/T14048.3 and IEC60947-3.
Code
GRGL-160/4
GR------Company Code
GL------Load Disconnect Switch
160----Rated Current
4:-------4 Phrase
Technical Parameters
| Code | GRGL-160/4 |
| Conventional thermal current (A) | 160 |
| Rated operating current (A) | 160 |
| Rated operating voltage (V) | 400 |
| Rated insulation voltage (V) | 750 |
| Rated impulse withstand voltage (kV) | 6 |
| Rated making capacity (A) | 160 |
| Rated breaking capacity (A) | 160 |
| Mechanical life (times) | 10000 |
| Electrical life (times) | 1000 |
| Short-time withstand current (kA/1s) | 10 |
| Operating force (N) | ≤400 |
| Pollution degree | 3 |
| Enclosure protection grade | IP00 |
Structure and Features
- The load-disconnector features a housing made of glass-fiber-reinforced unsaturated polyester resin.
- A spring-loaded acceleration mechanism enables rapid connection and disconnection.
- The contact structure features two separate contact surfaces with parallel double-break points, with contact pressure maintained by leaf springs.
- The disconnector automatically controls the open and close limits and features clear on/off markings to indicate the open and close positions.
Dimension

Installation Instructions
1. The switch should be installed vertically. Before installation, check the nameplate for compliance with operating requirements. Confirm that the switch is in the off position. Move the switch operating handle. When the arrow on the pointer points outside the "0" position and the observation window displays "0," the switch is in the off position. When the arrow points to the "I" position and the observation window displays "I," the switch is in the closed position.
2. The wiring terminals and bare busbars on the switch should be wrapped with insulation to prevent interphase short circuits.
3. If the extension shaft of the external switch is not aligned with the handle hole, do not move the extension shaft to avoid damage to internal components. Always adjust the switch position to ensure alignment.
4. The switch should be maintained approximately every six months. If the rotating parts are stiff, apply MP-3 grease. Check for loose fasteners and repair them accordingly. If damage is severe, discontinue use.
Safety Warning: Non-professional personnel are strictly prohibited from disassembling our products to avoid personal injury or equipment damage.
Our Advantage
This series of products can safely interrupt rated current and overload current within a certain range, effectively isolating faulty circuits and ensuring the safety of maintenance personnel.
A clearly visible "open/close" indicator window and reliable contact position indication prevent accidental operation. The high-grade enclosure (e.g., IP20) effectively protects against electric shock and dust intrusion.
As a factory, we offer a complete supply chain from mold development, injection molding, stamping, to assembly. We strictly control every step of the production process to provide you with highly competitive quality and pricing.
With strong production capacity and ample inventory, we ensure timely and accurate order delivery, ensuring that customers' project schedules and production plans are met.
FAQ
Q: What is the price?
A: Pls contact us, or leave messages. We'll reply to you ASAP.
Q: Do you offer OEM/ODM services?
A: Yes, we support OEM&ODM.
Q: Can I operate the disconnector outside the electrical cabinet?
A: Yes, we will provide accessories for operating it outside the cabinet. Please inform us before you quote.
Q: What shipping methods do you offer?
A: E.g., Express, Air Freight, Sea Freight, LCL/FCL